|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
40W AC-DC Single Output Desktop Features : GS40 series Universal AC input / Full range No load power consumption<0.3W Pass energy star (CEC) level for full series Meet energy star (CEC) level for full series Meet EISA 2007(Energy Independence and Security Act) 3 pole AC inlet IEC320-C14 Class power ( with earth pin) Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case LED indicator for power on Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE Pass LPS for full series 2 years warranty SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER (max.) OUTPUT VOLTAGE TOLERANCE Note.4 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT(max.) OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE Note.5 TUV Rheinland Product Safety geprUfre Sicherheit GS40A05-P1J GS40A07-P1J GS40A09-P1J GS40A12-P1J GS40A15-P1J GS40A18-P1J GS40A24-P1J GS40A48-P1J GS40A05 Note.2 5V GS40A07 7.5V 5.34A 0 ~ 5.34A 40W 100mVp-p 5.0% 1.0% 5.0% GS40A09 9V 4.45A 0 ~ 4.45A 40W 100mVp-p 5.0% 1.0% 5.0% GS40A12 12V 3.34A 0 ~ 3.34A 40W 100mVp-p 3.0% 1.0% 3.0% GS40A15 15V 2.67A 0 ~ 2.67A 40W 100mVp-p 3.0% 1.0% 3.0% GS40A18 18V 2.22A 0 ~ 2.22A 40W 150mVp-p 3.0% 1.0% 3.0% GS40A24 24V 1.67A 0 ~ 1.67A 40W 180mVp-p 2.5% 1.0% 2.5% GS40A48 48V 0.84A 0 ~ 0.84A 40W 240mVp-p 2.5% 1.0% 2.5% 5A 0 ~ 5A 25W 5.0% 1.0% 5.0% RIPPLE & NOISE (max.) Note.3 100mVp-p Note.7 600ms, 30ms / 230VAC 600ms, 30ms / 115VAC at full load 50ms / 230VAC 15ms / 115VAC at full load 90 ~ 264VAC 135 ~ 370VDC 47 ~ 63Hz 80.5% 1A / 115VAC 65A / 230VAC 0.75mA / 240VAC 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.25 ~ 6.75V 7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V Protection type : Shut down o/p voltage, re-power on to recover 0 ~ +60 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03% / (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 85.5% 0.5A / 230VAC 85% 89% 89.5% 90% 91% 92% 25.2 ~ 32.4V 50.4 ~ 64.8V SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC EMI CONDUCTION & RADIATION Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B (Note. 6) HARMONIC CURRENT Compliance to EN61000-3-2,3, GB17625.1 EMS IMMUNITY OTHERS MTBF DIMENSION PACKING PLUG CABLE Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 711Khrs min. MIL-HDBK-217F(25 125*50*31.5mm (L*W*H) 0.31Kg; 40pcs/13.4Kg/0.91CUFT Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested See page 2 ; Other type available by customer requested ) CONNECTOR NOTE 1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. File Name:GS40-SPEC 2008-10-22 40W AC-DC Single Output Desktop Mechanical Specification GS40 Case No. 974A series Unit:mm 31.5 125 UL1185 16AWG 1000 50mm for 5 ~ 15V UL1185 18AWG 1800 50mm for 18 ~ 48V 70 10mm 50 C"+" 11 0.5mm ID 2.1 x OD 5.5 Plug Assignment Standard plug: P1J (option) P1J P/N CENTER OUTPUT + Derating Curve Static Characteristics Ta=25 100 90 100 80 80 60 70 LOAD (%) LOAD (%) 0 10 20 30 40 50 60 70 40 60 50 40 20 (HORIZONTAL) 90 95 100 110 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:GS40-SPEC 2008-10-22 |
Price & Availability of GS40A09-P1J |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |